Track Structure for LWR

The minimum length required for a rail to function as an LWR depends upon the range of temperature variation, the section of the rail, the resistance offered by the ballast to the thermal expansion of the sleepers, and the resistance offered by the rail and sleeper assembly to any thermal expansion of the rails. Normally, a rail length of about 100 m on BG and 150 m on MG is subjected to thermal expansion at each rail end. Thus a length of more than 200 m on BG and 300 m on MG is generally necessary for a welded rail panel to function as an LWR.

17.4.1 Formation

The formation should not pose any problems in the laying of LWRs. In stretches where the formation is bad, it should be stabilized before the LWRs are laid. A cross slope of 1 in 40 should be provided at the time of screening and laying of LWRs. In the case of concrete sleeper tracks, an extra cess width is provided to the extent of 90 cm for embankments and 60 cm for cuttings.

17.4.2 Ballast

A clean ballast cushion of a minimum depth of 250 mm (10") should be provided below the bottom of the sleeper for LWRs. In order to increase resistance, the shoulder width of the ballast should measure 350 mm in the case of straight tracks

and the inside of curves and 500 mm in the case of the outer ends of curves. The ballast should also be humped to a height of 150 mm on both shoulders.

The typical ballast profiles for LWRs for single-line and double-line BG concrete sleeper tracks with a 250 mm (10") ballast cushion are given in Figs 17.2 and 17.3, respectively and are also, respectively, summarized in Tables 17.2 and 17.3.

Table 17.2 Ballast profile for single-line LWR track

Gauge

Sleeper

A

B

C

D

E

F

F1

H

Wooden

250

350

500

2270

2420

6850

6250

540

BG

Steel

250

350

500

2280

2430

6850

6250

590

Concrete

250

350

500

2525

2675

6850

6250

640

Wooden

250

350

500

1760

1930

5850

5250

510

MG

ST

250

350

500

1790

1940

5850

5250

520

CST/9

250

350

500

1730

1880

5850

5250

510

Concrete

250

350

500

2025

2175

5850

5250

590

All dimensions are in millimetres.

Table 17.3 Ballast profile for double-line LWR track

Gauge

Sleeper

A

B

C

D

E

F

F1

H

J

Wooden

250

350

500

2300

2340

12,155

10,210

570

5250

BG

Steel

250

350

500

2310

2350

12,155

10,210

580

5250

Concrete

250

350

500

2525

2460

12,155

10,980

700

5250

Wooden

250

350

500

1890

1810

9810

9210

535

3960

MG

ST

250

350

500

1890

1810

9810

9210

535

3960

CST/9

250

350

500

1750

1810

9810

9210

535

3960

Concrete

250

350

500

2025

1970

9810

9210

595

3960

All dimensions are in millimetres.

If followed by a non-LWR track, the ballast section and depth of the LWR track should be continued over the switch expansion joint or buffer rail assembly and also up to the rail lengths beyond it.

17.4.3 Sleepers Prescribed for LWR and CWR

The sleepers prescribed for LWR and CWR tracks are listed below.

Broad gauge (BG)

(i) Concrete sleepers with elastic fastenings.

(ii) Untreated or hard (U category) wooden sleepers with fastenings for speeds not exceeding 160 km/h.

(iii) Steel trough sleepers with elastic fastenings for speeds not exceeding 130 m/h (as an interim measure for speeds up to 160 m/h).

However, as an interim measure, steel trough sleepers with loose jaws and keys, untreated wooden sleepers, and CST-9 sleepers are also permitted.

Sleeper density for BG On BG tracks the sleeper density on LWR/CWR should be as follows:

GMT > 20 1660 sleepers per kilometre for all routes except the

E route, where 1540 sleepers per km may be permitted For GMT 10-20 1660 sleepers per kilometre for route A; 1540 per

kilometre for routes B, C, D, and E For GMT < 10 1660 sleepers per kilometre for route A; 1540 per

kilometre routes for B, C, and D, 1310 per kilometre for route E (1540 per kilometre if LWRs is provided).

Meter gauge (MG)

The prescribed sleepers for MG tracks are concrete sleepers, steel trough sleepers, durable wooden sleepers, and CST-9 sleepers.

Sleeper density for MG On MG tracks, the sleeper density should be 1540 sleepers per kilometre for speeds up to 100 km/h and 1660 sleepers per kilometre for speeds above 100 km/h. On the existing LWR/CWR tracks, the decision to retain or change the existing sleeper density is taken by the chief engineer.

Rails

LWRs should be laid with 60-kg, 52-kg, or 90 R rails on BG and 90 R or 75 R rails on MG barring the portions already laid with 60 R rails. Generally, new rails with fish bolt holes should not be used for LWRs. Further, level crossings should not fall within the breathing lengths of LWRs and switch expansion joints or buffer rails should be located at the end of the LWRs.

Prohibited Locations for LWR | RAILWAY ENGINEERING | Rail Temperature and its Measurement